The high limit switch shuts down the furnace at a set limit so a clog doesn t burn out the system.
Furnace high limit switch.
I believe high limit switches are normally closed and.
In this episode of repair and replace vance shows how to replace the high limit switch in a gas furnace.
It reads the temperature of the plenum and waits until it gets appropriately warm.
Rather it is wired in series with the 24 volt control circuit of your furnace.
The limit switch includes a sensor in the heat exchanger to.
If the blower came on at the same time as the burner it would pump cold air through the house at first.
The high temperature limit switch is an important device used in forced air furnaces powered by gas or heating oil.
The switch makes sure the furnace is operating safely and at its desired settings.
Rollout switches and high temperature fuses are different from limit switches in that when they open they will not close again unless reset as in the case of the rollout switch or replaced as in the case of the high temperature fuse.
For example if the blower motor stopped running then no air would move through the unit.
They will be mounted near where the flame may rollout the front of the furnace due to venting blockages heat.
When the high limit switch trips the flame heating element will be shut off and the blower will continue to run to clear the heat.
This is the role it plays in every cycle of your furnace s normal operation.
The limit switch is a safety switch that monitors t.
Remove the cover by lifting it upwards or pulling it off to reveal the body of the switch and two metal arms.
If the high limit switch was bad the furnace should not fire.
The flames would raise the temperature inside the unit and have no place to go getting hotter and hotter.
A limit switch is a device that s located under your furnace s supply plenum.
Note that the limit switch has nothing to do with the thermostat.
The high limit switch in your gas furnace is a small part with two very important jobs.
High limit switch a high limit control switch will turn off the gas to a furnace if the temperature becomes too high.
A pair of wires is connected to the switch.
Depending on your furnace model the switch will be surrounded by a silver or white cover.
Once the plenum reaches a specific temperature the limit switch sends a signal to the air handler to begin running and delivering warm air to your home.
This switch plays a role in the normal operation of your furnace.
As a safety the high limit.
Locate the white limit switch.
It will be located at the top of the panel.
The blower will continue to run until either the system is reset or the limit switch closes.